Pressures indicated in "bar" are gauge pressures.
Only pressures marked "abs" are absolute pressures.
|
|
|
|||
|
|
Power at the coupling |
normal |
144 |
kW |
|
|
|
max. |
200 |
kW |
|
|
|
|
|
|
|
|
Output speed |
min. |
- |
rpm |
|
|
|
normal |
1800 |
rpm |
|
|
|
max. |
- |
rpm |
|
|
|
|
|
|
|
|
Trip speed |
|
2070 |
rpm |
|
|
|
|
|
|
|
|
Gear transmission ratio |
|
5,04 |
|
|
|
|
|
|
|
|
|
Live steam pressure |
normal |
69,7 |
bar |
|
|
|
|
|
|
|
|
Live steam temperature |
normal |
286 |
°C |
|
|
|
|
|
|
|
|
Exhaust steam pressure |
normal |
3,8 |
bar |
|
|
|
|
|
|
|
|
Exhaust steam temperature |
maximal (limit value) |
150 |
°C |
|
|
|
|
|
|
|
|
Leakage steam to be led off pressure less |
|
|
|
|
|
|
|||
See steam flow diagram no.: 4140 024 35 64 (4) *
With a lower live steam pressure, a lower live steam temperature or a higher exhaust steam back pressure the design power is not achieved.