5       Operating data 4.140.682 / 683

 

5.0       Pressure indications

 

Pressures indicated in "bar" are gauge pressures.

            Only pressures marked "abs" are absolute pressures.

5.1       Operating data and limit value

 

 

 

 

 

Power at the coupling

normal

144

kW

 

 

max.

200

kW

 

 

 

 

 

 

Output speed

min.

-

rpm

 

 

normal

1800

rpm

 

 

max.

-

rpm

 

 

 

 

 

 

Trip speed

 

2070

rpm

 

 

 

 

 

 

Gear transmission ratio

 

5,04

 

 

 

 

 

 

 

Live steam pressure

normal

69,7

bar

 

 

 

 

 

 

Live steam temperature

normal

286

°C

 

 

 

 

 

 

Exhaust steam pressure

normal

3,8

bar

 

 

 

 

 

 

Exhaust steam temperature

maximal (limit value)

150

°C

 

 

 

 

 

 

Leakage steam to be led off pressure less

 

 

 

 

 

5.2       Design

            See steam flow diagram       no.: 4140 024 35 64 (4) *

 

With a lower live steam pressure, a lower live steam temperature or a higher exhaust steam back pressure the design power is not achieved.

 

* For the steam flow diagram please refer to part B of the operating manual